当前位置: 首页 > 图文教程 > 网络编程 > ASP > 怎样传送更多的数据在表单中

ASP
使用ASP和Word进行服务器端拼写检查
文本中首字母全改为大写
检测整数和长整数的函数
谈谈如何在不支持数据库的asp主页上运用ado
在多行文本框中显示读取信息
生成一个不重复的随即数字
网上追捕(很多实用的port)
用javascript隐藏超级链接的真实地址
给浏览器的滚动条加上颜色
asp+中是如何连接数据库ado+的
几个对图形进行动态处理的dhtml代码
域名登记查询(whois)很复杂吗--方法一
域名登记查询(whois)很复杂吗--方法二
用ASP创建多栏选项列表
asp中的一个奇怪的函数
瞒天过海html文件技术一瞥
如何在服务器上保存一定时间的信息
用ASP发 WAP MAIL(=)
创建弹出式“每日提示”窗口
用两行代码在浏览器中实现文件上传

ASP 中的 怎样传送更多的数据在表单中


出处:互联网   整理: 软晨网(RuanChen.com)   发布: 2009-11-03   浏览: 230 ::
收藏到网摘: n/a

  request对象限制102,399 bytes..
When you post a large form field, you may receive the following error message:

Error Type:
Request object, ASP 0107 (0x80004005)
The data being processed is over the allowed limit.

In Microsoft Internet Information Server (IIS) 4.0, you may receive the following error message:
Request object error 'ASP 0107 : 80004005'
Stack Overflow
/projectname/page.asp, line XX
The data being processed is over the allowed limit.


CAUSE
The size limit of each form field that is retrieved in the Request object is 102,399 bytes. The error
occurs when you exceed this limit.


RESOLUTION
To resolve this problem, use one of the following methods:

Instead of reading form variable values with the Request.Form collection, use Request.BinaryRead
(Request.TotalBytes), and parse the form values from the output of Request.BinaryRead.


Use a File Upload scheme, such as Microsoft Posting Acceptor.


Break the HTML form variables into multiple form variables before you submit the form. The 102,399 byte
limit is for each form variable, so you can have multiple form variables of 102,399 characters or less.
The following sample code illustrates this:
WARNING: ANY USE BY YOU OF THE CODE PROVIDED IN THIS ARTICLE IS AT YOUR OWN RISK. Microsoft provides this
code "as is" without warranty of any kind, either express or implied, including but not limited to the
implied warranties of merchantability and/or fitness for a particular purpose.

<FORM method=post action=LargePost.asp name=theForm onsubmit="BreakItUp()">
<Textarea rows=3 cols=100 name=BigTextArea>A bunch of text...</Textarea>
<input type=submit value=go>
</form>

<SCRIPT Language=JavaScript>
function BreakItUp()
{
//Set the limit for field size.
var FormLimit = 102399

//Get the value of the large input object.
var TempVar = new String
TempVar = document.theForm.BigTextArea.value

//If the length of the object is greater than the limit, break it
//into multiple objects.
if (TempVar.length > FormLimit)
{
document.theForm.BigTextArea.value = TempVar.substr(0, FormLimit)
TempVar = TempVar.substr(FormLimit)

while (TempVar.length > 0)
{
var objTEXTAREA = document.createElement("TEXTAREA")
objTEXTAREA.name = "BigTextArea"
objTEXTAREA.value = TempVar.substr(0, FormLimit)
document.theForm.appendChild(objTEXTAREA)

TempVar = TempVar.substr(FormLimit)
}
}
}
</SCRIPT>
The receiving Active Server Page (ASP) page reconstructs the variable:
<%
Dim BigTextArea

For I = 1 To Request.Form("BigTextArea").Count
BigTextArea = BigTextArea & Request.Form("BigTextArea")(I)
Next
%>