当前位置: 首页 > 图文教程 > 操作系统 > Unix/Linux > configuration utility for the RAIDframe disk drive

Unix/Linux
linux紧急救援模式
论学习
让你firefox快起来
我的fedora core 3汉化之旅
几个在线英汉字典网站
JPEG 简易文档 V2.11(转贴)
加罗华简介
怎么消除linux下的屏幕偏移现象和调整屏幕刷新率?
我哥哥去了西安做生意去了
2005第二号公告
squid的配置文件
尖峰时刻
grub硬盘安装hiweed-debian-desktop_0.55
hiweed0.55下xmms菜单乱码的解决
proftp详细配置一览
使用者管理--sudo
Windows 2003和Redhat Linux7.3安装问题
Find命令使用详解
今天开始找工作了
如何对系统做镜像以提高系统高可用性和性能

Unix/Linux 中的 configuration utility for the RAIDframe disk drive


出处:互联网   整理: 软晨网(RuanChen.com)   发布: 2009-11-01   浏览: 119 ::
收藏到网摘: n/a

RAIDCTL(8) OpenBSD System Manager's Manual RAIDCTL(8)NAME raidctl - configuration utility for the RAIDframe disk driverSYNOPSIS raidctl [-v] [-afFgrR component] [-BGipPsSu] [-cC config_file] [-A [yes | no | root]] [-I serial_number] dev
DESCRIPTION raidctl is the user-land control program for raid(4), the RAIDframe disk device. raidctl is primarily used to dynamically configure and unconfig- ure RAIDframe disk devices. For more information about the RAIDframe disk device, see raid(4). This document assumes the reader has at least rudimentary knowledge of RAID and RAID concepts. The device used by raidctl is specified by dev. dev may be either the full name of the device, e.g. /dev/rraid0c, or just simply raid0 (for /dev/rraid0c). For several commands (-BGipPsSu), raidctl can accept the word all as the dev argument. If all is used, raidctl will execute the requested action for all the configured raid(4) devices. The command-line options for raidctl are as follows: -a component dev Add component as a hot spare for the device dev. -A yes dev Make the RAID set auto-configurable. The RAID set will be auto- matically configured at boot before the root file system is mounted. Note that all components of the set must be of type RAID in the disklabel. -A no dev Turn off auto-configuration for the RAID set. -A root dev Make the RAID set auto-configurable, and also mark the set as be- ing eligible to contain the root partition. A RAID set config- ured this way will override the use of the boot disk as the root device. All components of the set must be of type RAID in the disklabel. Note that the kernel being booted must currently re- side on a non-RAID set and, in order to have the root file system correctly mounted from it, the RAID set must have its `a' parti- tion (aka raid[0..n]a) set up. -B dev Initiate a copyback of reconstructed data from a spare disk to its original disk. This is performed after a component has failed, and the failed drive has been reconstructed onto a spare drive. -c config_file dev Configure the RAIDframe device dev according to the configuration given in config_file. A description of the contents of config_file is given later. -C config_file dev As for -c, but forces the configuration to take place. This is required the first time a RAID set is configured. -f component dev This marks the specified component as having failed, but does not initiate a reconstruction of that component. -F component dev Fails the specified component of the device, and immediately be- gin a reconstruction of the failed disk onto an available hot spare. This is one of the mechanisms used to start the recon- struction process if a component does have a hardware failure. -g component dev Get the component label for the specified component. -G dev Generate the configuration of the RAIDframe device in a format suitable for use with raidctl -c or -C. -i dev Initialize the RAID device. In particular, (re-write) the parity on the selected device. This MUST be done for all RAID sets be- fore the RAID device is labeled and before file systems are cre- ated on the RAID device. -I serial_number dev Initialize the component labels on each component of the device. serial_number is used as one of the keys in determining whether a particular set of components belong to the same RAID set. While not strictly enforced, different serial numbers should be used for different RAID sets. This step MUST be performed when a new RAID set is created. -p dev Check the status of the parity on the RAID set. Displays a sta- tus message, and returns successfully if the parity is up-to- date. -P dev Check the status of the parity on the RAID set, and initialize (re-write) the parity if the parity is not known to be up-to- date. This is normally used after a system crash (and before a fsck(8)) to ensure the integrity of the parity. -r component dev Remove the spare disk specified by component from the set of available spare components. -R component dev Fails the specified component, if necessary, and immediately be- gins a reconstruction back to compone